搜索结果: 1-15 共查到“医学 Titanium”相关记录79条 . 查询时间(0.046 秒)
Titanium+gold = new gold standard for artificial joints
Titanium gold new gold standard artificial joints
2016/8/1
Titanium is the leading material for artificial knee and hip joints because it’s strong, wear-resistant and nontoxic, but an unexpected discovery by Rice University physicists shows that the gold stan...
Oesophago-Cutaneous Fistula Due to a Broken Titanium Plate of Anterior Cervical Plate Fixation
Oesophago-Cutaneous Broken Titanium Plate Anterior Cervical Plate Fixation
2015/9/23
Anterior cervical spine fusion and plate fixation is a valuable procedure for the treatment of cervical spinal injury, spondylitic disease and intervertebral disc diseases.1 Esophageal perforation is ...
A comparative study of frictional resistance of stainless steel, nickel titanium, TMA, timolium & CNA archwires with stainless steel brackets - An in vitro study
comparative study frictional resistance stainless steel nickel titanium
2010/11/3
A comparative study of frictional resistance of stainless steel, nickel titanium, TMA, timolium & CNA archwires with stainless steel brackets - An in vitro study .
Study of corrosion of combinations of titanium/Ti-6Al-4V implants and dental alloys
Implant Dissolution of metal ions Micro-structure of titanium
2010/11/30
Metal ions released in 1% lactic acid solution from combinations of titanium fixtures with superstructures made of dental precious metal alloys (dental alloys) and titanium and differences based on th...
Effects of sandblasting media and steam cleaning on bond strength of titanium-porcelain
Bond strength of titanium-porcelain Sandblasting media Steam cleaning
2010/11/29
The effects of sandblasting media and steam cleaning treatment after sandblast were examined on tensile bond strength of porcelain to titanium. The use of the commercially available silica-coated alum...
Effects of α-DT cement with hydroxypropyl cellulose on bone augmentation within a titanium cap in the rabbit calvarium
Guided bone regeneration Bone grafts Histology
2010/11/26
The present study was performed to evaluate the effects of calcium phosphate cement (α-DT cement) containing α-TCP, dicalcium phosphate anhydrous, and tetracalcium phosphate mixed with hydroxypropyl c...
Improved brushing durability of titanium dioxide coating on polymethylmethacrylate substrate by prior treatment with acryloxypropyl trimethoxysilane-based agent for denture application
Brushing wear Surface morphology Titanium dioxide
2010/11/26
The purpose of this study was to determine whether the brushing durability of a titanium dioxide coating on a polymethyl methacrylate (PMMA) substrate was improved by prior treatment with an acryloxyp...
Corrosion behavior of ion implanted nickel-titanium orthodontic wire in fluoride mouth rinse solutions
Ni-Ti wire Corrosion Plasma immersion ion implantation
2010/11/26
This study investigated the corrosion properties of ion implanted nickel-titanium wire (Neo Sentalloy Ionguard) in artificial saliva and fluoride mouth rinse solutions (Butler F Mouthrinse, Ora-Bliss)...
Photocatalytic bactericidal action of fluorescent light in a titanium dioxide particle mixture: an in vitro study
titanium dioxide particle mixture vitro
2009/12/16
Traditional titanium dioxide (TiO2) has photocatalytic bactericidal properties only under ultraviolet (UV) irradiation, which restricts its use in clinical treatment regimens. In this study, we evalua...
Influence of titanium dioxide nanoparticles on speciation and bioavailability of arsenite
Arsenic TiO 2 Nanoparticles Bioaccumulation Carp Facilitated transport
2013/12/12
In this study, the influence of the co-existence of TiO2nanoparticles on the speciation of arsenite [As(III)]was studied by observing its adsorption and valence changing. Moreover, the influence of Ti...
Response of osteoblastic cells to titanium submitted to three different surface treatments
Titanium Surface properties Osteoblasts Biocompatible materials
2009/10/20
In the complex process of bone formation at the implant-tissue interface, surface properties are relevant factors modulating osteoblastic function. In this study, commercially pure titanium (cp Ti) sa...
The influence of mold temperature on the fit of cast crowns with commercially pure titanium
Marginal adaptation Crowns Titanium Dental casting investment
2009/10/19
Commercially pure titanium (CP Ti) has been widely applied to fabricate cast devices because of its favorable properties. However, the mold temperature recommended for the manufacture of casts has bee...
Characterization of titanium surfaces for dental implants with inorganic contaminant
Titanium Dental implants Aluminum oxide Image processing computer-assisted
2009/10/19
The aim of this research was to characterize titanium surfaces blasted with aluminum oxide (Al2O3) particles using the KS 400 digital image processing program. Samples of grade II titanium plates were...
Evaluation of titanium implants with surface modification by laser beam: biomechanical study in rabbit tibias
Dental implants Lasers Osseointegration
2009/10/16
The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined ...
Effects of Welding Pulse Energy and Fluoride Ion on the Cracking Susceptibility and Fatigue Behavior of Nd:YAG Laser-welded Cast Titanium Joints
Welding pulse energy Fluoride Mechanical property
2009/9/15
In this study, the cracking susceptibility and fatigue behavior of Nd:YAG laser-welded cast Ti joints (welding pulse energy: 11, 15, and 18 J) in fluoride-containing (0 and 0.5% NaF) artificial saliva...